MAINTENANCE
PRINT DRUM INDEX MECHANISM CONVERSION
1- Using a 5/64” hex wrench, loosen the Nylon Tip Set Screw
located in the top rim of the Print Drum.
2- Remove the Print Drum Dust Cover.
3- To relieve the spring tension on the index mechanism, ro-
tate the Print Drum approximately 3/4 turn. The Index Com-
pression Springs will now be in the fully extended (relaxed)
position.
FIGURE 57
FIGURE 58
FIGURE 59
4- Using a 5/32" hex wrench, remove the two Index Ramp Mount-
ing Screws which are located on the under side of the Coder
Baseplate. The Index Ramp will be reinstalled in the oppo-
site orientation to allow the Print Drum to turn in the reverse
direction.
FIGURE 60