Maintenance 6-7
Battery Replacement
WARNING: There is a danger of explosion if the battery is incorrectly replaced.
Replace the battery only with the same or equivalent type recommended by the
battery manufacturer. Using an incorrect battery, recharging or disassembling the
battery may present a danger due to fire or explosion. Dispose of used batteries
promptly according to the local regulations.
Cooling Fan Filters
This air-cooled laser system will require periodic
cleaning of the cooling fan filters. Since ambient air
is used to cool the laser tube, the air must be filtered
before it enters the inside of the laser system
otherwise dirt and dust can build up inside of the
laser system and damage it. The contaminants
reduce the laser system’s cooling ability and will
cause the laser tube to overheat. An overheated
tube will lose laser power during engraving and will
eventually shut down completely. The laser tube
has a built in safety mechanism that will shut the
beam off before it can damage itself.
The cooling fan filters are located on the back of the
laser system. To service the filters, first unplug the
laser system. Unlatch the rear laser cover and lift it
open. The filters are located where the arrows are
pointing in the illustration. To remove the filter(s),
simply snap off the black cover and remove the foam
element. Wash the element in a soap and water
solution, dry, and re-install.
NEVER OPERATE THE LASER SYSTEM WITH THE COOLING FAN FILTERS
REMOVED. This can permanently damage the laser system. Damage from this
kind of abuse WILL NOT be covered under warranty.